{"id":11164,"date":"2025-09-26T09:55:08","date_gmt":"2025-09-26T07:55:08","guid":{"rendered":"https:\/\/schmiertec.de\/produkt\/uncategorized\/lincoln-central-lubrication-pump-qls-301-standard\/"},"modified":"2025-09-26T09:55:08","modified_gmt":"2025-09-26T07:55:08","slug":"lincoln-central-lubrication-pump-qls-301-standard","status":"publish","type":"product","link":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/","title":{"rendered":"Lincoln central lubrication pump QLS 301 Standard"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>Lincoln grease pump type QLS 301 in the standard version, i.e. in a configuration that is most frequently required.<br \/>\nThis includes features such as:<br \/>\n&#8211; Operating pressure: max. 205 bar<br \/>\n&#8211; With empty indicator<br \/>\n&#8211; Standard delivery rate: approx.1 cm\u00b3\/min<br \/>\n&#8211; Lubricant distributor SSV mounted<br \/>\n&#8211; Lubricants: greases up to NLGI II<br \/>\n&#8211; Operating temperature: -25 \u00b0C to 70 \u00b0C<br \/>\n&#8211; Spring-loaded follower plate<br \/>\n&#8211; Filling via grease nipple<br \/>\n&#8211; Connections:<br \/>\n1 \u00d7 left for power supply (V DC \/ V AC) cube plug; for industrial applications<br \/>\n1 \u00d7 right for external fill level monitoring (empty signal)<br \/>\nor fault indicator, cube plug; for industrial applications<br \/>\n&#8211; Dimensions: max. 237 \u00d7 235 \u00d7 270 mm  <\/p>\n","protected":false},"featured_media":0,"template":"","meta":[],"product_brand":[],"product_cat":[610,609],"product_tag":[716,615,611,613,614,612,719,720,718,717,721],"class_list":{"0":"post-11164","1":"product","2":"type-product","3":"status-publish","5":"product_cat-central-lubrication-units","6":"product_cat-grease-lubrication","7":"product_tag-automatic-lubrication","8":"product_tag-bearing-lubrication","9":"product_tag-central-lubrication","10":"product_tag-central-lubrication-system","11":"product_tag-central-lubrication-unit","12":"product_tag-grease-lubrication","13":"product_tag-grease-lubricator","14":"product_tag-grease-pump","15":"product_tag-lincoln-pump","16":"product_tag-skf-pump","17":"product_tag-slideway-lubrication","18":"pa_spannung-12-vdc","19":"pa_spannung-230-vac","20":"pa_spannung-24-vdc","21":"pa_steuerung-with","22":"pa_steuerung-without","24":"first","25":"instock","26":"sale","27":"taxable","28":"shipping-taxable","29":"purchasable","30":"product-type-variable"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lincoln central lubrication pump QLS 301 Standard - SchmierTec<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lincoln central lubrication pump QLS 301 Standard - SchmierTec\" \/>\n<meta property=\"og:description\" content=\"Lincoln grease pump type QLS 301 in the standard version, i.e. in a configuration that is most frequently required. This includes features such as: - Operating pressure: max. 205 bar - With empty indicator - Standard delivery rate: approx.1 cm\u00b3\/min - Lubricant distributor SSV mounted - Lubricants: greases up to NLGI II - Operating temperature: -25 \u00b0C to 70 \u00b0C - Spring-loaded follower plate - Filling via grease nipple - Connections: 1 \u00d7 left for power supply (V DC \/ V AC) cube plug; for industrial applications 1 \u00d7 right for external fill level monitoring (empty signal) or fault indicator, cube plug; for industrial applications - Dimensions: max. 237 \u00d7 235 \u00d7 270 mm\" \/>\n<meta property=\"og:url\" content=\"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/\" \/>\n<meta property=\"og:site_name\" content=\"SchmierTec\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/produkt\\\/grease-lubrication\\\/central-lubrication-units\\\/lincoln-central-lubrication-pump-qls-301-standard\\\/\",\"url\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/produkt\\\/grease-lubrication\\\/central-lubrication-units\\\/lincoln-central-lubrication-pump-qls-301-standard\\\/\",\"name\":\"Lincoln central lubrication pump QLS 301 Standard - SchmierTec\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/#website\"},\"datePublished\":\"2025-09-26T07:55:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/produkt\\\/grease-lubrication\\\/central-lubrication-units\\\/lincoln-central-lubrication-pump-qls-301-standard\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/schmiertec.de\\\/en\\\/produkt\\\/grease-lubrication\\\/central-lubrication-units\\\/lincoln-central-lubrication-pump-qls-301-standard\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/produkt\\\/grease-lubrication\\\/central-lubrication-units\\\/lincoln-central-lubrication-pump-qls-301-standard\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Lincoln central lubrication pump QLS 301 Standard\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/\",\"name\":\"SchmierTec\",\"description\":\"Kettenschmierung und Zentralschmierung\",\"publisher\":{\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/#organization\",\"name\":\"STW - Kim Friedrich GmbH\",\"alternateName\":\"SchmierTec\",\"url\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/schmiertec.de\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Logo_Startseite.png\",\"contentUrl\":\"https:\\\/\\\/schmiertec.de\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Logo_Startseite.png\",\"width\":1700,\"height\":1701,\"caption\":\"STW - Kim Friedrich GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/schmiertec.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lincoln central lubrication pump QLS 301 Standard - SchmierTec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/","og_locale":"en_US","og_type":"article","og_title":"Lincoln central lubrication pump QLS 301 Standard - SchmierTec","og_description":"Lincoln grease pump type QLS 301 in the standard version, i.e. in a configuration that is most frequently required. This includes features such as: - Operating pressure: max. 205 bar - With empty indicator - Standard delivery rate: approx.1 cm\u00b3\/min - Lubricant distributor SSV mounted - Lubricants: greases up to NLGI II - Operating temperature: -25 \u00b0C to 70 \u00b0C - Spring-loaded follower plate - Filling via grease nipple - Connections: 1 \u00d7 left for power supply (V DC \/ V AC) cube plug; for industrial applications 1 \u00d7 right for external fill level monitoring (empty signal) or fault indicator, cube plug; for industrial applications - Dimensions: max. 237 \u00d7 235 \u00d7 270 mm","og_url":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/","og_site_name":"SchmierTec","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/","url":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/","name":"Lincoln central lubrication pump QLS 301 Standard - SchmierTec","isPartOf":{"@id":"https:\/\/schmiertec.de\/en\/#website"},"datePublished":"2025-09-26T07:55:08+00:00","breadcrumb":{"@id":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/schmiertec.de\/en\/produkt\/grease-lubrication\/central-lubrication-units\/lincoln-central-lubrication-pump-qls-301-standard\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/schmiertec.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/schmiertec.de\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Lincoln central lubrication pump QLS 301 Standard"}]},{"@type":"WebSite","@id":"https:\/\/schmiertec.de\/en\/#website","url":"https:\/\/schmiertec.de\/en\/","name":"SchmierTec","description":"Kettenschmierung und Zentralschmierung","publisher":{"@id":"https:\/\/schmiertec.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/schmiertec.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/schmiertec.de\/en\/#organization","name":"STW - Kim Friedrich GmbH","alternateName":"SchmierTec","url":"https:\/\/schmiertec.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/schmiertec.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/schmiertec.de\/wp-content\/uploads\/2024\/01\/Logo_Startseite.png","contentUrl":"https:\/\/schmiertec.de\/wp-content\/uploads\/2024\/01\/Logo_Startseite.png","width":1700,"height":1701,"caption":"STW - Kim Friedrich GmbH"},"image":{"@id":"https:\/\/schmiertec.de\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/product\/11164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/product\/11164\/revisions"}],"wp:attachment":[{"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/media?parent=11164"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11164"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11164"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schmiertec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}